Beam Bending Stress Calculator
Bending, shear and von Mises stress with a yield safety factor.
Calculate the maximum bending stress and shear stress in a beam section from bending moment and shear force. Section properties for I-beams, rectangular tubes, round tubes, round bars and flats are computed for you, including the first moment of area Q for shear.
- Live results
- Full step-by-step working
- PASS / FAIL checks
- Free PDF report
Results
Step-by-step calculation (7 steps)
- 1Second moment of areaFormulaI = [B·H³ − (B−tw)(H−2tf)³] / 12SolutionI = [80 × 150³ − 75 × 134³] / 12ResultI = 7461850 mm⁴ (746.2 cm⁴)
- 2Section modulusFormulaZ = I / cSolutionZ = 7461850 / 75ResultZ = 99491 mm³
- 3Maximum bending stressFormulaσ = M·c / ISolutionσ = 1×10⁷ × 75 / 7461850Resultσ = 100.5 MPa
- 4First moment of area at neutral axisFormulaQ = B·tf·(H−tf)/2 + tw·((H−2tf)/2)²/2SolutionQ = 80 × 8 × 142/2 + 5 × 67²/2ResultQ = 56663 mm³, b = 5 mm
- 5Maximum shear stressFormulaτ = V·Q / (I·b)Solutionτ = 20000 × 56663 / (7461850 × 5)Resultτ = 30.37 MPa
- 6Von Mises equivalent stress (conservative)Formulaσvm = √(σ² + 3τ²)Solutionσvm = √(100.5² + 3 × 30.37²)Resultσvm = 113.4 MPa
- 7Safety factor on yieldFormulan = Sy / σvmSolutionn = 250 / 113.4Resultn = 2.2 ≥ 1.5PASS
Engineering takeaways
- Combining peak σ (outer fibre) and peak τ (neutral axis) is conservative: the two maxima occur at different points. For I-beams also check the web-flange junction.
- Under fatigue (cyclic) loads use the endurance limit and weld detail category (EN 1993-1-9), not yield strength.
- Open sections in bending need a lateral-torsional buckling check when the compression flange is not restrained.
I-section 150 × 80, tw 5, tf 8 mm (no root radii)
The PDF report contains every input, formula, substitution and check shown above, in LTM calculation-sheet format.
Worked Example
The calculator combines the two into a conservative von Mises equivalent stress and compares it with the yield strength of E250, S355, stainless 304, aluminium 6061-T6 or your own material.
The calculator above opens with this example. Change any input to run your own case.
Inputs
| Bending moment M | 10000 N·m |
|---|---|
| Shear force V | 20000 N |
| Section profile | I-beam / H-beam |
| Width / flange width B | 80 mm |
| Height H | 150 mm |
| Web thickness tw | 5 mm |
| Flange thickness tf | 8 mm |
| Material | Structural steel IS 2062 E250 / S235 (Sy 250 MPa) |
| Required safety factor | 1.5 |
Results
| Bending stress σ | 100.5 MPa |
|---|---|
| Shear stress τ | 30.37 MPa |
| Von Mises σvm | 113.4 MPa |
| Safety factor | 2.2 PASS |
Bending Stress Formulas Used
Bending stress
- Mbending moment
- cdistance to extreme fibre
- Isecond moment of area
Shear stress
- Vshear force
- Qfirst moment of area above neutral axis
- bwidth at neutral axis
Von Mises stress
Safety factor
Basis: Euler-Bernoulli bending; Jourawski shear formula; von Mises criterion. Results are for preliminary design and should be confirmed against supplier data and the governing standard.
Bending Stress Calculator FAQ
How do I calculate bending stress in a beam?
Multiply the bending moment by the distance from the neutral axis to the outer fibre, and divide by the second moment of area: σ = M·c/I. With M in N·mm and dimensions in mm, the result is in MPa.
Where is shear stress highest?
At the neutral axis, where bending stress is zero. In an I-beam almost all shear is carried by the web, so τ ≈ V / (web height × web thickness) is a good quick check.
Why is combining peak values conservative?
Peak bending stress is at the outer fibre and peak shear at the neutral axis, so they do not occur at the same point. Adding them in von Mises gives an upper bound. In I-beams, check the web-flange junction where both are significant.
What safety factor should I use?
For static loads on ductile steel, 1.5 on yield is common in machine design. Use higher factors for uncertain loads, and use fatigue methods with weld detail categories for cyclic loads.
Which yield strength is E250?
IS 2062 E250 has a minimum yield of 250 MPa for thickness up to 20 mm, similar to S235 in EN 10025. E350 / S355 has 350 to 355 MPa.
Related Calculators
Need more than a calculator?
Send a short brief with sketches or specifications. You get a clear scope and a fixed quote, usually within one business day.